Deployment NameGliderProjectDeployedRecoveredDaysDistancePayload BayOSNotes
bios_minnie-20170616T1406bios_minnieBIOS2017-06-16
14:06Z
2017-09-11
19:35Z
87.2338.8 km92657.20

All Notes (9)

Created by: dkaragon @ 2017-09-13 08:47:44Informational

Fore leak detect triggered, .5 V running in low power mode so was 'low' for maybe 10 min. Cleared by the time it reached surface. Never tripped again drifting.

Recovered by AE 9/11 ~ 3 EST

Created by: administrator @ 2017-09-06 17:41:44Informational

Increased nocomms to 10 hours

Created by: administrator @ 2017-09-06 04:08:41Informational

Conserving battery in advance of potential hurricane encounter next week: 575 amphrs used
Double yos to 950m
Turned SUNA off
CTD, FLBB, Optode sampling on dives only

Created by: administrator @ 2017-08-19 10:07:36Informational

Increased pump throw on climb: -230 / +140

Created by: administrator @ 2017-08-09 07:01:56Informational

underwater reset near 200 m on the climb
nothing appears out of order

loadmission minnie.mi
sequence 1k_n2.mi(5)

Created by: administrator @ 2017-07-13 12:25:31Informational

Dives to 950
double yos
sampling CTD,O2,FLBB on dives
CTD,SUNA on climbs

Created by: administrator @ 2017-07-01 09:34:14Informational

Begin diurnal experiment
Dives to 500 m, double yos
sampling on dives and climbs
SUNA on climbs only

Created by: administrator @ 2017-06-20 13:17:30Informational

longterm_put f_fin_safety_max 0.35
put x_fin_max 0.04
put f_fin_deadzone_width 0.04
put x_fin_deadband 0.04

sequenced 1k_n2
pump throw -230 /140
dives to 950m, double yos

Created by: administrator @ 2017-06-19 08:48:27Informational

Deployed 15-Jun-2017 by AE @ BATS site
CTD 9265
FLBB 3771
Optode 541
SUNA 642

CTD pump likely not working (large d/u T-S shift in thermocline)