All Notes (10)
Glider was not floating properly at surface. Likely air system failure
Vacuum record shows it happened on the last day.
Recovered by David Aragon, Chip Haldeman aboard NJDEP vessel with Captain Rodney Sloan out of Atlantic City, NJ.
Comparison CTD cast done at recovery using RBRConcerto
Uncharacteristic bottom sample:
ru28_2023_029_3_166
Altimeter readings look accurate, backing off dive to altitude.
Back to TBD every 3rd from 6
All sensors every -3rd yo now
Optics every -3rd yo
CTD cross comparison HURRICANE RBR
TBDlist was borked, fixed it
load_mission(): Opening Mission file: RU28.MI
Setting SENSOR u_abort_min_burn_time(sec) value 600.000000
Setting SENSOR u_abort_max_burn_time(sec) value 28800.000000
Setting SENSOR u_reqd_depth_at_surface(m) value 2.000000
Setting SENSOR u_hd_fin_ap_run_time(secs) value 12.000000
Setting SENSOR u_hd_fin_ap_gain(1/rad) value 1.500000
Setting SENSOR u_hd_fin_ap_igain(1/rad-sec) value 0.015000
Setting SENSOR u_hd_fin_ap_dgain(sec/rad) value 6.000000
Setting SENSOR u_hd_fin_ap_hardover_holdoff(sec) value 30.000000
Setting SENSOR u_pitch_ap_gain(1/rad) value -1.000000
Setting SENSOR u_pitch_ap_dgain(s/rad) value -1.000000
Setting SENSOR u_pitch_ap_deadband(rad) value 0.079000
Setting SENSOR f_battpos_db_frac_dz(nodim) value 1.000000
Setting SENSOR u_min_pitch_ap_period(sec) value 2.000000
Setting SENSOR u_max_pitch_ap_period(sec) value 60.000000
Operating System: 8.3
Instruments:
Seabird CTD
0103p
3/27/2022
Wetlabs ECO-Puck FLBBCD-SLC
3326
5/4/2021
Aanderaa Optode 5014W
1504
4/27/2021
Vemco VMT
ID 59965
Strap-on, no data feed through glider
Deployed by Tim Stolarz, Teemer Barry, and Danielle Brown out of Belmar aboard NJDEP vessel with boat captain Rich Rand.