All Notes (6)
Recovered by Katherine H. and Harrison S. out of UDEL. Cast performed about 20 min after last glider yo due to miscommunication.
Turned CC off, switched tbd to every 4th yo. To try to go faster.
bottom sampling
put u_min_water_depth 0
Noisy altimeter now on at least the last 2 coastal missions (2018).
Seems to be getting short sighted hits as it dives despite reqd num = 3 so its getting multiple. Looks like there is a band at 30 m so for now:
!!!!! U_MIN_WATER_DEPTH 30 !!!!!!!!!!!!!!
Can't solve it with u_min/max alt or num hits. Filter I have no idea, disabling probably doesn't help.
Deployed by Matt Oliver, K. Hudson, H. Smith out of UDEL.
Intitial attempt at deployment Th 11/8 had top culprit problems: pitch sensor or pitch batt disconnected. This lead to it diving at +30, climbing at +50, no response to pitch movement.
2nd test dive with max battpos fwd on dive and aft on climb resulted in expected -40+ and +40 pitch angles. Darkness and lack of time lead to it being pulled back onboard. Pitch battery 'mostly' connected and no pitch or compass problems on land.
OS 8.2
# seabird CTD #9178
# Wetlabs FLBBCD #3424
# Aanderaa #0334
# Vemco #450142
# Vemco #450143