Deployment ru33-20211001T1841
Pilot Notes
Current urider.ini # uRider.ini # This is the Rockland Scientific MicroRider (MICRORIDER) proglet initialization file # # This file is used to configure proglet specific parameters, # configuration parameters take the format: #
:
# # 2017-08-08 mbrissette@teledyne.com Initial # 2017-12-13 mbrissette@teledyne.com Mantis 4054: increase parameter POWER_WAIT_SECS from 30 to 60 # 2021-02-03 mbrissette@teledyne.com Mantis 5650: Rockland Scientific MicroRider DL-3 support # The MicroRider Sensor Type parameter tells the proglet the device type. This is # necessary for specific device messages and state machine transitions # 0 - MicroRider(1000) # 1 - MicroRider(DL-3) SENSOR_TYPE: 1 # The MicroRider(DL-3 specific) Initial Status Delay tells the proglet to wait this # long before querying the device status. # n - seconds to wait prior to sending initial status query message DL3_INITIAL_STATUS_DELAY_SECS: 150 # The MicroRider(DL-3 specific) Status Interval Seconds tells the proglet how often # to query the device status. Internal status data is only updated every 90 seconds, # using a value < 90 is not recommended. # n - seconds between status query messages DL3_STATUS_INTERVAL_SECS: 300 # The MicroRider(DL-3 specific) Max Status Response Wait Seconds tells the proglet # how long to wait for the Status Response data. # n - seconds to wait for the status response data DL3_MAX_STATUS_RESPONSE_WAIT_SECS: 10 # The Max Message Wait Seconds attribute determines how long the proglet # will wait for a Verbose Console Output message. The absence of a message within # this time is an indication that the MicroRider's internal flash memory is full. # n - maximum seconds to wait for a Verbose Console Output message MAX_MESSAGE_WAIT_SECS: 60 # The Maximum Number of messages to store sets the limit for the number of messages # stored in the 'xxxxxxxx.mrd' files, per proglet start. The file may contain more # than STORE_MAX_MSGS if there are multiple proglet starts within a segment. # n - store 'n' mesages maximum to the 'xxxxxxxx.mrd' file. # a value of -1 indicates no maximum STORE_MAX_MSGS: 60 # ################################################################################# # The following parameters should only be changed when directed by Teledyne support # ################################################################################# # The Diag Level parameter is used to capture diagnostic information, this should only # be changed at Teledynes request. When the diag level is > 0, output is generated to # the science terminal and the science NLG file. # 0 - DIAG_LEVEL_OFF, normal mode of operation, errors are reported. # 1 - DIAG_LEVEL_1, proglet trace info. # 2 - DIAG_LEVEL_2, DIAG_LEVEL1 + message tracing. # 3 - DIAG_LEVEL_3, DIAG_LEVEL_2 with output to glider. DIAG_LEVEL: 2 # The Number of Errors attribute determines how many errors will be detected before # a failing status is returned and a restart is generated. # n - Number of acceptable errors. NUM_ERRORS: 0 # The Power Wait Seconds attribute determines how long the proglet waits before communicating # with the device after enabling power. This may need to be increased based on device bootup # time. A "state 'WAIT_INITIAL_PROMPT', no initial prompt" is an indication of the issue. # n - seconds to wait before accessing the device after enabling power. POWER_WAIT_SECS: 60 # The Command Prompt Wait Seconds attribute determines how long the proglet will # wait for the command prompt # n - maximum seconds to wait for the command prompt before generating an error. CMD_PROMPT_MAX_WAIT_SECS: 10 # The Sync Clock attribute determines if the proglet updates the time on the device # n - 0 = do not update the device time, 1 = update the device time. SYNC_CLOCK: 1 # The Stop Sampling Max Wait Seconds attribute determines how long the proglet # will wait for a response before removing power from the device # n - maximum seconds to wait for a response prompt before removing power STOP_MAX_WAIT_SECS: 10
Category
Informational
Alert
Action Needed
Action Taken
Operations
Update
Credentials Required
Username
Password