Fleet Configurations
Deployments
Gliders
Projects
Payload Bays
Instruments
Users
API
Log In
Deployment ru30-20210226T1647
Pilot Notes
Downloaded MLG from missed call ins: 119681 Iridium, modem making attempt #1 at secondary number (17818711614) 119685 81 Iridium driver received:[ATE1[0D][0D]] 119686 Iridium modem matched: OK 119686 Waking up Iridium... sending:AT+cbst=6,0,1 119690 81 Iridium driver received:[AT+cbst=6,0,1[0D][0D]] 119690 Iridium modem matched: OK 119690 Waking up Iridium... sending:AT+CSQ 119695 83 Iridium driver received:[AT+CSQ[0D][0D][0A]+CSQ:0[0D][0A][0D]] 119695 Iridium modem matched: OK 119700 84 Iridium waiting for registration... 119709 86 Obtaining Iridium RSSI... 119709 Iridium dialing [ATD0017818711614]........... 119709 Iridium waiting for connection... 119714 87 Iridium driver received:[ATD0017818711614[0D]] 119728 90 Iridium waiting for connection... 119728 Iridium driver received:[[0D]] 119728 Iridium modem matched: NO CARRIER 119733 90 DRIVER_ODDITY:iridium:9:retry due to Iridium reporting NO CARRIER 119733 DRIVER_ODDITY:iridium:4148:secs; cycling Iridium power 119746 93 Iridium has been powered on for 8.4 secs 119746 Waking up Iridium... sending:ATE1 Similar to previous missed call instances with most CSQ being 0. Missed calls from 2/28 00:47 to 06:56 Got GPS during those calls it appears. Vacuum looks to be getting lower over time at surfacings.
Category
Informational
Alert
Action Needed
Action Taken
Operations
Update
Credentials Required
Username
Password