Deployment ru33-20191014T1643
Pilot Notes
Lithium performance post recovery: Recovered 11/15/2019, analyzed 1/23/2020, 69 days ---> ~ 20% SD possible in those days 167 AH used as reported by glider Batteries did not discharge evenly, see table below: Total reported charge level = 60.9/227.9 AH ---> 227.9-60.9 = 167 AH If we include SD that is about 152 used AH Match level with glider 100% and 110% as reported by glider. Emailing TWR to see if they should be discharging equally. Cell Serial Volts Charge_AH Capacity_AH Percent_Charge Percent_Mean_Capacity ____ ______ ______ _________ ___________ ______________ _____________________ 1 103 13.66 6.744 9.55 71 96 2 111 13.662 7.025 9.615 73 97 3 119 13.664 1.411 9.366 15 95 4 136 13.663 1.311 9.319 14 94 5 147 13.668 6.784 9.522 71 96 6 150 13.662 1.459 9.533 15 96 7 167 13.666 6.823 9.568 71 97 8 182 13.661 7.019 9.487 74 96 9 754 13.582 1.405 10.121 14 102 10 760 13.584 1.425 10.097 14 102 11 864 13.581 1.427 10.117 14 102 12 868 13.581 1.497 10.203 15 103 13 888 13.574 1.44 10.084 14 102 14 890 13.58 1.493 10.126 15 102 15 901 13.591 1.563 10.308 15 104 16 902 13.568 1.477 9.946 15 100 17 935 13.588 1.566 10.245 15 103 18 936 13.574 1.442 10.122 14 102 19 939 13.586 1.56 10.222 15 103 20 950 13.585 1.542 10.129 15 102 21 955 13.58 1.531 10.134 15 102 22 956 13.574 1.499 9.992 15 101 23 961 13.583 1.485 10.053 15
Category
Informational
Alert
Action Needed
Action Taken
Operations
Update
Credentials Required
Username
Password