Pilot Notes
Lithium post recovery analysis: 136 AH used by glider Cells were about 3.65 AH / 10.08 AH -- (if we account for SD rate @ .3%/day then we had about 4 AH/cell at recovery (this note about 30 days past recovery) 4 AH remaining thus about 6/10 burned for mission --> 6 * 23 = 138 AH roughly matching glider. If we didn't account for SD rate it would be about 146 AH used Thus glider reads 1 to 7% lower than batteries. Fairly good agreement as it might be more towards the 1% than 7%. With 10% remaining on cells as a buffer, about 1 AH we had a remaining 2.65 AH on these cells. 2.65 * 23 = 60 AH. 136 + 60 = 195 total AH.