Pilot Notes
• 4 series, possibly 116 cells need to confirm • 10 C average sci_wateR_temp • Rough guess 28 AH @ 10 C • De-rate 3% for self drain / EOL, assume batteries were new going into mission, mission lasted a year, 5% for EOL • 116/4 = 29 29 * 28 = 812 812 * .97 * .95 = 748 AH • Batteries started to fall at about 671 or so, had completely fallen at 692 • Roughly obtained 93% of rated capacity