Fleet Configurations
Deployments
Gliders
Projects
Payload Bays
Instruments
Users
API
Log In
Deployment ru34-20240301T1336
Pilot Notes
# This is the Jasco, Observer Hydrophone, OBSVR proglet initialization file # # This file is used to configure proglet specific parameters, # configuration parameters take the format: #
:
# # 2018-08-14 mbrissette@teledyne.com Initial # 2019-04-08 mbrissette@teledyne.com Increased POWER_UP_MAX_WAIT_SECS from 20 to 40 # 2022-02-07 mbrissette@teledyne.com G3S-508: JASCO obsvr and amar, increased power up timer to 150 seconds # 2024/02/01 dkaragon increased errors and timers # ################################################################################# # The following parameters should only be changed when directed by Teledyne support # ################################################################################# # The Diag Level parameter is used to capture diagnostic information, this should only # be changed at Teledynes request. When the diag level is > 0, output is generated to # the science terminal and the science NLG file. # 0 - DIAG_LEVEL_OFF, normal mode of operation, errors are reported. # 1 - DIAG_LEVEL_1, proglet trace info. # 2 - DIAG_LEVEL_2, DIAG_LEVEL1 + device message tracing. DIAG_LEVEL: 1 # The Number of Errors attribute determines how many errors will be detected before # a failing status is returned and a restart is generated. # n - Number of acceptable errors. NUM_ERRORS: 10 # The Power Wait Seconds attribute determines how long the proglet waits before communicating # with the device after enabling power. # n - seconds to wait before accessing the device after enabling power. POWER_UP_MAX_WAIT_SECS: 150 # The Message Response Timeout Seconds attribute determines how long the proglet will # wait for a response from the device. # n - maximum seconds to wait for a response before generating an error. MSG_RESPONSE_TIMEOUT_SECS: 20 # The Telemetry Update Interval Seconds attribute determines how ofter the telemetry data # is sent to the device # n - 0 = do not update the telemetry data, n = how often the telemetry data is updated. TELEMETRY_UPDATE_INTERVAL_SECS: 300 # The Query Status Interval Seconds attribute determines how ofter the proglet queries the # device status. # n - 0 = do not query the status, n = how often to query the status. QUERY_STATUS_INTERVAL_SECS: 300 # The Power Down Wait Secs attribute determines how long the proglet # will wait after sending the Shutdown message before removing power # n - seconds to wait after sending the Shutdown message before removing power POWER_DOWN_WAIT_SECS: 40
Category
Informational
Alert
Action Needed
Action Taken
Operations
Update
Credentials Required
Username
Password