All Notes (9)
Recovered by Brian, Jess, Delphine on SeaTow Atlantic City.
recovered with RU32 and RU40.
comparison ctd cast done with Sb19 1383 on Rosette.
water sampling done with rosette (surface and thermocline) and niskin (bottom) due to length of line available on davit for rosette.
net tows done.
All sensors to +3 sampling except CTD on all the time (7)
Some profiles with pumped ctd issue?
Also ru39, 40 analyze altimeter data for deep off shelf performance.
All RUDICS gliders (not ru29 dod) sufferred iridium problems Th 6pm to about 3 pm Fri. Emails with iridium said RF noise problem but strangely issue got fixed within an hour or 2 of emailing them. All gliders switched to TWR for about a day.
load_mission(): Opening Mission file: ru39.mi
Setting SENSOR u_abort_min_burn_time(sec) value 600.000000
Setting SENSOR u_abort_max_burn_time(sec) value 64800.000000
Setting SENSOR u_reqd_depth_at_surface(m) value 2.000000
Setting SENSOR u_hd_fin_ap_run_time(secs) value -1.000000
Setting SENSOR u_hd_fin_ap_gain(1/rad) value 1.500000
Setting SENSOR u_hd_fin_ap_igain(1/rad-sec) value 0.015000
Setting SENSOR u_hd_fin_ap_dgain(sec/rad) value 8.000000
Setting SENSOR u_hd_fin_ap_hardover_holdoff(sec) value 30.000000
Setting SENSOR u_pitch_ap_gain(1/rad) value -1.000000
Setting SENSOR u_pitch_ap_dgain(s/rad) value -1.000000
Setting SENSOR u_pitch_ap_deadband(rad) value 0.052400
Setting SENSOR f_battpos_deadzone_width(inches) value 0.200000
Setting SENSOR f_battpos_db_frac_dz(nodim) value 0.500000
Setting SENSOR u_min_pitch_ap_period(sec) value 2.000000
Setting SENSOR u_max_pitch_ap_period(sec) value 60.000000
CTD state 7 all
AZFP state 3 all
pH, FLBBCD -3 to match with TBD
Operating System: 10.08
Instruments:
Seabird pumped CTD
9918
10/13/2022
Seabird pH
12177
11/8/2022
WetLabs FLBBCD-SLC
7698
8/3/2022
ASL AZFP
59024
1/30/2023
120, 200, 455, 769kHz
Vemco VMT
1564555
ID51594; Strap-on, no data flow through glider
Deployed by Nicole Waite, Jessica Leonard, and Delphine Mossman aboard TowBoat US out of Manasquan, NJ.
Deployed with RU40 and RU32.
Comparison CTD case done with SB19 s/n 1581 and ballast tank laptop.
Net tows done at deployment.
Water samples for pH taken with Rosette with SB19 s/n 1383 and ballast tank laptop.