All Notes (6)
Glider suffered 2 underwater resets diving to around 400 m.
m_why_started was 128
app start from pico or control c after exit or exit reset = 16
plug cycle slow (while powered up) = 64
plug cycle fast (while powered up) = 128
SBU01 software crash = 32
Glider keeps resetting whenever it dives deeper than 150-200 meters (150 is fine). Don't have many data points on this.
Limping east for a recovery tomorrow by Matt and Antonio.
Up to 200!.... at next surfacing
2 resets for hardware:
sensor: m_why_started(enum) 128 # 128 -> External (the reset button)
Happened while diving to 400 meters. No diagnostics on issue because reset happened mid segment so 0 byte file. Testing shallower dives at first. So far one successful 100 meter dive.
Deployed by Chip Haldeman, Casey Jones, Steve Prosterman and Matt Souza aboard the University of the Virgin Islands research vessel Hindsight out of St Thomas, USVI.
OS 8.3
Seabird CTD sn 9408p cal 2/10/2022
Aanderra Optode 4831 (Oxy4) sn 952 cal 2/14/2021 Checked in house 5/18/22
AD2CP sn 101591 cal 4/23/2020
Acousonde3A sn B003A055 no cal date, No live data nor data flow through glider