All Notes (9)
this is for this glider only
Science Payload:
CTD-0121
bbfl2s-667
bb3slo 645
bbam 026G
RU23 aborted for high vacuum; indicative of air bladder leak. Currently drifting on surface, u_max_time_in_gliderdos 5400, callback 30 cycle. Alan Hails will attempt to arrange recovery early a.m.
use - science_super
sbd changed to reflect no science data
trying to last another week or so due to storms.
buoyancy pump abort, related to remora, likely tried to move the pump too fast and caused problems
fractured tests at surface showed it moving, have to reset system several times to get liths back online
Another GPS abort, GPS apparently working, resequenced.
Likely a surface abort again since glider was due up. Did not pull MLG.
ABORT HISTORY: total since reset: 7
ABORT HISTORY: last abort cause: MS_ABORT_DEVICE_ERROR
ABORT HISTORY: last abort time: 2010-08-11T13:50:35
ABORT HISTORY: last abort segment: ru23-2010-217-4-72 (0069.0072)
ABORT HISTORY: last abort mission: 100_TN.MI
Glider aborted for GPS too many warnings while on the surface at the end of the segment, for whatever reason. Because of this device out of service the lithium batteries did not come back online.
use + lithium would not remedy, but a single exit reset did.
4 hour missions
Lithium ion rechargeables