Pilot Notes
RU29 aborted ~12am local time, Friday, July 1 with a leak. Fore triggered first, but both aft and forward have water. Abort happened at 768m on the dive - quick drop in the leak detect readings. There is a little bump in the pressure record at this time too, but only up 0.2m. RU29 then got stuck on the climb from the abort at 150m, until it shot the weight, and then got to the surface vacuum has been steadily dropping since surfacing for the abort. Vacuum was 7.9 at first call-in (12am), 6.4 at 2am