Deployment blue-20220301T1433
Pilot Notes
Aborted for buoyancy pump. 'not reading position' on a climb to dive transition. MBD shows pump may have lagged 1-2 cycles before moving but that could be normal. Need DBD to determine exactly when the dive occurred. Previous pump oddities from mission were OOD that didn't look like much. Same segment as abort it seems like on the first climb to dive it got held at surface? Pump was all the way in according to m_ballast_pumped but it was stuck at surface for a minute before diving. Very strange. Nothing in roll from that, heading it got turned 50 deg starboard, pitch was flat so flat at surface? Need NBD or EBD there to cross check pressure sensors, but it looks fairly real.