Deployment ru34-20210208T2055
Pilot Notes
176 AH used by glider which is 78% if we go by battery capacity of 225. 68.862 / 225.226 AH = 70% used by battery report. 8.5/23 batteries showed higher than average charge. Rest showed about 1AH or so. Seems like glider more accurate thus maybe those cells are indeed discharging? Appears in this case most of the high reporting cells are in the pitch not registers 0,1 Perhaps 82% according to voltage curve (just a guess). Cell Serial Volts Charge_AH Capacity_AH Percent_Charge Percent_Mean_Capacity 1 208 13.535 6.113 9.751 63 100 2 424 13.548 1.217 9.837 12 100 3 431 13.553 5.717 9.826 58 100 4 436 13.547 6.442 9.792 66 100 5 437 13.55 5.031 9.745 52 100 6 445 13.549 6.68 9.674 69 99 7 464 13.546 1.159 9.764 12 100 8 468 13.549 6.172 9.741 63 99 9 469 13.544 3.886 9.807 40 100 10 492 13.548 6.778 9.795 69 100 11 517 13.551 6.509 9.783 67 100 12 970 13.525 1.129 9.973 11 102 13 975 13.528 1.068 9.759 11 100 14 977 13.528 1.08 9.855 11 101 15 983 13.532 0.983 9.867 10 101 16 991 13.531 1.147 9.828 12 100 17 1043 13.525 1.091 9.608 11 98 18 1052 13.531 1.122 9.892 11 101 19 1054 13.528 1.115 9.885 11 101 20 1055 13.528 1.044 9.75 11 100 21 1056 13.518 0.979 9.679 10 99 22 1058 13.525 1.129 9.763 12 100 23 1193 13.549 1.271 9.852 13 101 Mean battery charge level: 2.994 / 9.7924 Total charge level (all battery charges summed): 68.862 / 225.226