Pilot Notes
Taken from ru26d\'s previous deployment: According to datasheet, we have 30 AH batteries nominal. Derating: Temperature plot (datasheet) says 23.3 AH at -2 C which is about 22% derating Average current is about 277 mA Lets derate 1 year for shelf life, 3%, and lets say 25% derating for safety: 30 Ah * .75 * .97 = 21.825 AH We have 26 x 3 DD cells, so total AH is 26 * 21.825 = 567.45 AH