Deployment ru29-20221116T1326
Pilot Notes
undervolts abort. Checked quickest example I could find ru25 amundsen with alkalines. That voltage sagged 3.5 V from 13V to about 9.5 V It drew a little over 6 A Previous ru29 deployment at 14.4 V sagged only 1.5 V but pump drew same little over 6 A Probably 8.5 V is getting low which is upper voltage of 8.5+ 3.5 = 12 V should shallow it up by then.