Deployment Status
Notes (9)
Altimeter might be shot turning off just in case.
Blue 200 m pump with Blue Li Ion
Leak detects holding steady it 'naturally' settled to about 2.3 V from 2.0 v over a few days.
Vacuum also holding steady.
All RUDICS gliders (not ru29 dod) sufferred iridium problems Th 6pm to about 3 pm Fri. Emails with iridium said RF noise problem but strangely issue got fixed within an hour or 2 of emailing them. All gliders switched to TWR for about a day.
Foward leak detected. 5/2 00 GMT front leak detect showed faint signs of something there but ultiamtely triggered at 2V at 40 m down after a long surfacing.
Drifted glider for 24 hours
Trying to swim, lowered safety timers and set overdepth to 50 m for mission.
CHeck previous surfacing, script didn't issue ctrl F after file transfer hangup.
FLBBCD every -3rd yo
Deployed by Patrick Pasteris and Miles Sundermeyer, aboard the F/V Encourager out of New Bedford, MA
Operating System: 8.3
Instruments:
Seabird GPCTD
9699
2/26/2021
Wetlabs FLBBCDSLC
4474
06/04/2019
Aanderaa Oxygen Optode 3830
1273
04/09/2021