        "attrs": {
            "calibration_date": "2021-06-26",
            "calibration_report": " ",
            "comment": "Pumped",
            "deployment": " ",
            "factory_calibrated": "2021-06-26",
            "long_name": "Conductivity, Temperature, Depth (CTD) Sensor",
            "make_model": "Sea-Bird GPCTD",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "9646P",
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/9646P-ctd.yml",
        "nc_var_name": "instrument_ctd",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2020-06-17",
            "calibration_report": " ",
            "comment": "Chlorophyll a,beta700nm,CDOM",
            "deployment": " ",
            "factory_calibrated": "2020-06-17",
            "long_name": "ECO Triplet Puck",
            "make_model": "Sea-Bird ECO Triplet flbbcdslc",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "6312",
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/6312-flbbcdslc.yml",
        "nc_var_name": "instrument_flbbcdslc",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2021-04-27",
            "calibration_report": " ",
            "comment": "in-house check 2022-02-14",
            "deployment": " ",
            "factory_calibrated": "2022-04-27",
            "long_name": "Oxygen Optode",
            "make_model": "Aanderaa Oxygen Optode 5014W",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "1504",
            "type": "instrument",
            "user_calibrated": "2022-02-14"
        },
        "cfg_file": "/home/coolgroup/slocum/cals/1504-optode.yml",
        "nc_var_name": "instrument_optode",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "1970-01-01",
            "calibration_report": " ",
            "comment": "No calibration date available; head SN 111",
            "deployment": " ",
            "factory_calibrated": "1970-01-01",
            "long_name": "DMON",
            "make_model": "WHOI Digital Acoustic Monitoring Instrument DMON",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "3A231D06",
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/3A231D06-dmon.yml",
        "nc_var_name": "instrument_dmon",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "1970-01-01",
            "calibration_report": " ",
            "comment": "No calibration date available",
            "deployment": " ",
            "factory_calibrated": "1970-01-01",
            "long_name": "Vemco Rx-LIVE Cabled Receiver",
            "make_model": "Vemco Rx-LIVE Cabled Receiver",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "457001",
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/457001-vemco.yml",
        "nc_var_name": "instrument_vemco",
        "type": "i4"
    }
]