        "attrs": {
            "calibration_date": "2021-05-11",
            "calibration_report": " ",
            "comment": "Pumped",
            "deployment": " ",
            "factory_calibrated": "2021-05-11",
            "long_name": "Conductivity, Temperature, Depth (CTD) Sensor",
            "make_model": "Sea-Bird GPCTD",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "103P",
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/103P-ctd.yml",
        "nc_var_name": "instrument_ctd",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2021-05-04",
            "calibration_report": " ",
            "comment": "Chlorophyll a,beta700nm,CDOM",
            "deployment": " ",
            "factory_calibrated": "2021-05-04",
            "long_name": "ECO Triplet Puck",
            "make_model": "Sea-Bird ECO Triplet flbbcdslc",
            "platform": "platform",
            "serial_number": "3326",
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/3326-flbbcdslc.yml",
        "nc_var_name": "instrument_flbbcdslc",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2021-06-29",
            "calibration_report": " ",
            "comment": "in-house check 2021-10-14",
            "deployment": " ",
            "factory_calibrated": "2021-06-29",
            "long_name": "Oxygen Optode",
            "make_model": "Aanderaa Oxygen Optode 3835",
            "owner": "Rutgers University",
            "platform": "platform",
            "serial_number": "971",
            "type": "instrument",
            "user_calibrated": "2021-10-14"
        },
        "cfg_file": "/home/coolgroup/slocum/cals/971-optode.yml",
        "nc_var_name": "instrument_optode",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2021-10-29",
            "calibration_report": " ",
            "comment": "DMCS calibration, not factory cal",
            "deployment": " ",
            "factory_calibrated": " ",
            "long_name": "Sequoia Scientific LISST 200x",
            "make_model": "Sequoia Scientific LISST 200x",
            "owner": "RU-COOL",
            "platform": "platform",
            "serial_number": "7003",
            "type": "instrument",
            "user_calibrated": "2021-10-29"
        },
        "cfg_file": "/home/coolgroup/slocum/cals/7003-lisst.yml",
        "nc_var_name": "instrument_lisst",
        "type": "i4"
    }
]