        "attrs": {
            "calibration_date": "2020-09-09",
            "calibration_report": " ",
            "comment": "Inductive conductivity, temperature, pressure  sensor",
            "deployment": " ",
            "factory_calibrated": "2020-09-09",
            "long_name": "RBR CTD",
            "make_model": "RBRconcerto CTD",
            "owner": "VIMS",
            "platform": "platform",
            "serial_number": 207227,
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/207227-ctd.yml",
        "nc_var_name": "instrument_ctd_rbr",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2021-08-01",
            "calibration_report": " ",
            "comment": " ",
            "deployment": " ",
            "factory_calibrated": "2021-08-01",
            "long_name": "Oxygen Optode",
            "make_model": "Aanderaa Oxygen Optode 4831",
            "owner": "VIMS",
            "platform": "platform",
            "serial_number": 910,
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/910-optode.yml",
        "nc_var_name": "instrument_optode",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2021-03-18",
            "calibration_report": " ",
            "comment": "Chlorophyll a,beta700nm,CDOM",
            "deployment": " ",
            "factory_calibrated": "2021-03-18",
            "long_name": "ECO Triplet Puck",
            "make_model": "Sea-Bird ECO Triplet flbbcdslc",
            "owner": "VIMS",
            "platform": "platform",
            "serial_number": 6745,
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/6745-flbbcdslc.yml",
        "nc_var_name": "instrument_flbbcdslc",
        "type": "i4"
    },
    {
        "attrs": {
            "calibration_date": "2020-08-17",
            "calibration_report": " ",
            "comment": "Measures PAR 400-700nm",
            "deployment": " ",
            "factory_calibrated": "2020-08-17",
            "long_name": "Photosynthetically Active Radiation (PAR) Sensor",
            "make_model": "Biospherical PAR QSP2155 Radiometer",
            "owner": "VIMS",
            "platform": "platform",
            "serial_number": 50340,
            "type": "instrument",
            "user_calibrated": " "
        },
        "cfg_file": "/home/coolgroup/slocum/cals/50340-bsipar.yml",
        "nc_var_name": "instrument_bsipar",
        "type": "i4"
    }
]