389.25 Iridium console active and ready... Vehicle Name: unit_197 Curr Time: Fri Sep 2 18:15:09 2011 MT: 389 DR Location: 3505.334 N -12046.444 E measured 0.773 secs ago GPS TooFar: 69696969.000 N 69696969.000 E measured 1e+308 secs ago GPS Invalid : 3505.743 N -12046.330 E measured 336.246 secs ago GPS Location: 3505.335 N -12046.446 E measured 301.577 secs ago sensor:m_battery(volts)=15.298869603034 4.242 secs ago sensor:m_iridium_signal_strength(nodim)=5 12.702 secs ago sensor:m_leakdetect_voltage(volts)=2.49590964590965 346.189 secs ago sensor:m_leakdetect_voltage_forward(volts)=2.48852258852259 346.206 secs ago sensor:m_vacuum(inHg)=6.91849816849817 4.44 secs ago ABORT HISTORY: total since reset: 4 ABORT HISTORY: last abort cause: MS_ABORT_OVERDEPTH ABORT HISTORY: last abort time: 2011-09-02T18:10:25 ABORT HISTORY: last abort segment: unit_197-2011-244-3-0 (0083.0000) ABORT HISTORY: last abort mission: ODCTD.MI 389.81 No login script found for processing. 452.25 88 DRIVER_WARNING:attitude_rev:-4:Error making periodic measurement sequence 200_tn!w.mi(5) Sequencing missions load_mission(): Opening Mission file: 200_TN!W.MI for execution 5 times Setting SENSOR c_science_send_all(bool) = 0.000000 Setting SENSOR c_science_all_on_enabled(bool) = 1.000000 Setting SENSOR u_dbd_sensor_list_xmit_control(enum) = 1.000000 Setting SENSOR u_sci_dbd_sensor_list_xmit_control(enum) = 2.000000 load_mission(): Opening Mission file: lastgasp.mi for execution FOREVER 1 mission specifiers - sequencing 5 total missions (not counting lastgasp.mi): 200_TN!W.MI(5) lastgasp.mi ABORT HISTORY: total since reset: 4 ABORT HISTORY: last abort cause: MS_ABORT_OVERDEPTH ABORT HISTORY: last abort time: 2011-09-02T18:10:25 ABORT HISTORY: last abort segment: unit_197-2011-244-3-0 (0083.0000) ABORT HISTORY: last abort mission: ODCTD.MI SEQUENCE: About to run 200_TN!W.MI on try 0 You have 120 seconds to type a control-C to terminate the sequence. The control-P character immediately starts the mission. All other characters are ignored. ^P Heard a control-P, starting the sequence SEQUENCE: Running 200_TN!W.MI on try 0 Starting Mission: 200_TN!W.MI The instantaneous lag time between the system and gps clock is -8.0 seconds. The average lag time between the system and gps clock is -1.9 seconds. timestamp: Fri Sep 2 18:17:52 2011 load_mission(): Opening Mission file: 200_TN!W.MI Setting SENSOR c_science_send_all(bool) = 0.000000 Setting SENSOR c_science_all_on_enabled(bool) = 1.000000 Setting SENSOR u_dbd_sensor_list_xmit_control(enum) = 1.000000 Setting SENSOR u_sci_dbd_sensor_list_xmit_control(enum) = 2.000000 Vehicle Name: unit_197 Curr Time: Fri Sep 2 18:17:53 2011 MT: 549 DR Location: 3505.334 N -12046.444 E measured 0.614 secs ago GPS TooFar: 69696969.000 N 69696969.000 E measured 1e+308 secs ago GPS Invalid : 3505.743 N -12046.330 E measured 499.55 secs ago GPS Location: 3505.335 N -12046.446 E measured 464.879 secs ago sensor:m_battery(volts)=15.2763011977358 2.7 secs ago sensor:m_iridium_signal_strength(nodim)=5 175.973 secs ago sensor:m_leakdetect_voltage(volts)=2.49590964590965 509.454 secs ago sensor:m_leakdetect_voltage_forward(volts)=2.48852258852259 509.466 secs ago sensor:m_vacuum(inHg)=6.91551398046398 2.876 secs ago start_alldevices() PARSED iridium_phone_data for datum# 0: =========== predial initialization cmds (from c:\config\iridinit.0): ATE AT+cbst=6,0,1 AT+CSQ dial string: ATD00881600005125 from sensors: C_IRIDIUM_LEAD_ZEROS C_IRIDIUM_PHONE_NUM Iridium login script (from c:\config\loginexp.0): empty or non-existent PARSED iridium_phone_data for datum# 1: =========== predial initialization cmds (from c:\config\iridinit.1): ATE AT+cbst=6,0,1 AT+CSQ dial string: ATD0015085482446 from sensors: C_IRIDIUM_LEAD_ZEROS_ALT C_IRIDIUM_PHONE_NUM_ALT Iridium login script (from c:\config\loginexp.1): empty or non-existent 67.57 2 00840000.mlg LOG FILE OPENED MissionSTARTDate: 02 Sep 2011 18:17:53 Z