Pilot Notes
According to datasheet, we have 30 AH batteries nominal. Derating: Temperature plot (datasheet) says 23.3 AH at -2 C which is about 22% derating Average current is about 277 mA Lets derate 1 year for shelf life, 3%, and lets say 25% derating for safety: 30 Ah * .75 * .97 = 21.825 AH We have 26 x 3 DD cells, so total AH is 26 * 21.825 = 567.45 AH We have used 81 AH as of today, which gives us 567.45 - 81 AH = 486.45 AH left for 56 days which means we can burn about 8.68 AH / day. As of right now we are at < 6.5 AH / day so we are good.